Medical equipment DM7000 Defibrillator Monitor inhospital

Short Description:

Screen Size: 8 inches diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm
On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy


Product Detail

Product Tags

Display
Screen Size: 8 inches diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm
On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy

Defibrillator
Waveform: Biphasic
Energy Display: Monitor display indicates both
selected and delivered energy
Charge Prompt Type: Voice and visual prompts
Electrode Impedance Measurement Range: 0-250 ohms
ECG Monitoring
Patient Connection: 3-lead ECG cable, or 5-lead ECG
cable, paddles
Lead Selection: Displayed on monitor, paddles, I, II, III,
AVR, AVL, AVF, V
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate: 20-300BPM
Heart Rate Alarm: On/Off displayed on monitor, user-selectable Smart Alarms: Beeper/voice prompts indicate shockable rhythm
N P (Optional)
Measurement unit: mmHg/ kPa
Measurement Range: Adult: 10 〜270 mmHg
Pediatric: 10 ~ 200 mmHg
Neonatal: 10 ~ 135 mmHg
Resolution: 1 mmHg
Accuracy: Maximum Mean error: 5 mmHg
Maximum Standard deviation: 8 mmHg
SpO2 Module (Optional)
Measurement Range: 30-100%, ± 2% between 80%~90%,
others ±5%
Alarm Range: User set high limit and low limit
Alarm Accuracy: ± 10% within setting values
Alarm time Accuracy: less than 12 sec
Recorder
Paper: 50mm thermal
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec.
User-selectable 6-second delay
Printing Method: High-resolution, thermal array print head
Print-out Modes: Manual or automatic, user-configurable On/Off Control: Front panel and paddle
Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge
AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts
Shockable Rhythms: Ventricular fibrillation
Ventricular tachycardia
QRS complex wave duration
Charge Control: Control on device front panel,
press key on paddle
Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70,100, 150, 200, 300, 360 joules
Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor

 